UI Tile Irrigation

Price range: $100.00 through $125.00

The CPLLC UI Tile Irrigation is a Crestron Home tile for up to 20 irrigation zones the installer names.

SKU: CPLLC.UITile.Irrigation Categories: , , ,

Description

The CPLLC UI Tile Irrigation is a Crestron Home tile for up to 20 irrigation zones the installer names. Each zone can be started and stopped from its row on the tile’s page, runs for its own run time in minutes and then stops by itself, and has “<zone> Started” and “<zone> Stopped” events. Start All and Stop All run or stop every zone at once. It is for UI purposes only: it drives no valves by itself, so sequences on its events turn the real valves on and off.

Drivers->UI Tiles->Control Programming LLC->Irrigation (Latest OS3 Release Notes) (Download OS3 Latest Version)

Drivers->UI Tiles->Control Programming LLC->Irrigation (Latest OS4 Release Notes) (Download OS4 Latest Version)

Windows utility that simplifies sideloading of drivers and extensions.

The extension’s own license key, or a CPLLC site license key, is entered in the extension’s Enter License Key option. The License Manager is not required, but it is the convenient place to enter a site license key once for every CPLLC driver.

All license purchases are final and non-refundable. Every CPLLC driver works fully for two hours without a key: test it on your processor before you buy. See the Terms of Use.

Installer Options

  • Obtain License Key – Opens CPLLC.net, where license keys and site licenses can be purchased.
  • Enter License Key – The Irrigation license key. Leave blank when the site has a CPLLC site license.
  • Show on Home Screen – Shows the tile on the Home screen (default off).
  • Show in Room Screen – Shows the tile in its room (default on).
  • Starting Pin Code – A numeric PIN that must be entered before the zones are shown. Blank means no PIN (the default). A new Starting Pin Code replaces a PIN changed from the keypad, so a forgotten PIN can be reset here.
  • Seconds Pin Active – How long the zones stay unlocked after the last touch (default 10 seconds; 0 also means 10).
  • Zone 01 – 20 – The zone’s name, shown on its row and its page, in its events (“<name> Started”, “<name> Stopped”) and in the zone list of the Zone sequences. Leave blank to leave the zone out. Give each zone a different name: the sequences find a zone by its name.

Actions

  • Zone Start – Starts the zone chosen by name (zone) for the number of minutes given (minutes, 1 to 120). 0, or minutes left out, runs it for the run time on its page.
  • Zone Stop – Stops the zone chosen by name.
  • Zone Toggle – Starts the zone chosen by name for its run time, or stops it while it runs.
  • Zone All Start – Starts every named zone, each for its own run time.
  • Zone All Stop – Stops every named zone.
  • Extension Enable / Extension Disable – Enables or disables the tile. A disabled tile shows Disabled and its zones can’t be started; a running zone still stops when its time is up.

Events

  • <zone> Started – The zone started: from its row, its page, Start All or a sequence. Put what opens the zone’s valve in a sequence on this event.
  • <zone> Stopped – The zone stopped: from its row or page, Stop All, a sequence, or its run time running out. Put what closes the zone’s valve in a sequence on this event.
  • Extension Enabled / Extension Disabled – The tile was enabled or disabled.
  • Pin Locked / Pin UnLocked – The PIN keypad locked again, or the right PIN was entered.

Additional information

Crestron Home OS Version

OS3, OS4