Description
Requires Crestron Home OS 4.12 or later.
The CPLLC Ecowitt Weather Station extension brings an Ecowitt weather station and its sensors into Crestron Home. The gateway posts every reading to the processor by itself (its Customized upload), so the extension needs no account or cloud and polls nothing. It shows the outdoor weather (temperature, humidity, pressure, wind, rain with the day’s total, UV, solar radiation, lightning) and the gateway’s extra sensors: room temperature and humidity sensors, soil moisture probes, leak detectors and PM2.5 air quality sensors. Its events start sequences when rain starts or stops, lightning strikes nearby, a leak detector gets wet, the wind rises above a limit, or the temperature, humidity, UV or rain pass the limits the installer sets.
Drivers->Sensor->Ecowitt->Weather Station (Latest Release Notes) (Download Latest Version)
Windows utility that simplifies sideloading of drivers and extensions.
The extension’s own license key, or a CPLLC site license key, is entered in the extension’s Enter License Key option. The License Manager is not required, but it is the convenient place to enter a site license key once for every CPLLC driver.
All license purchases are final and non-refundable. Every CPLLC driver works fully for two hours without a key: test it on your processor before you buy. See the Terms of Use.
Installer Options
- Obtain License Key – Opens CPLLC.net, where license keys and site licenses can be purchased.
- Enter License Key – The Ecowitt license key. Leave blank when the site has a CPLLC site license.
- Show on Home Screen – Shows the tile on the Home screen (default off).
- Show in Room Screen – Shows the tile in its room (default on).
- Starting Pin Code – A numeric PIN that must be entered before the page opens. Blank means no PIN (the default).
- Seconds Pin Active – How long the page stays unlocked after the last touch (default 10 seconds).
- Temperature Scale – The units the page shows: As Reported (°F with metric otherwise), Fahrenheit (°F, mph, inches, inHg, miles) or Celsius (°C, km/h, mm, hPa, km). The limits below are in the same units.
- Lightning Distance – Lightning Detected is raised for a strike no farther than this, in miles (Fahrenheit) or km (default 10; 0 for every strike).
- Wind Limit – Wind Above Limit is raised when a gust reaches this speed, in mph (Fahrenheit) or km/h, and Wind Below Limit once gusts fall under 80% of it (default 0, none).
- High Temperature / Low Temperature – Temperature Above / Below High Limit around the high one, Temperature Below / Above Low Limit around the low one. Blank for none.
- High Humidity / Low Humidity – Humidity Above / Below High Limit and Humidity Below / Above Low Limit, in percent. Blank for none.
- UV Limit – UV Above / Below Limit around this UV index. Blank for none.
- Heavy Rain – Heavy Rain Started when the rain rate per hour rises above this (inches with Fahrenheit, else mm), Heavy Rain Stopped when it falls back. Blank for none.
- Rain Today Limit – Rain Today Above Limit when the day’s rain passes this, Rain Today Below Limit when the day’s count starts again. Blank for none.
- Port – The port the gateway posts to, 1024 to 65535 (default 8088): the same as Port in WS View Plus.
- Path – The path the gateway posts to (default /data/report/, WS View Plus’s own): the same as Path in WS View Plus.
- Gateway PASSKEY – Only where several gateways post here: the PASSKEY of the one to show. Blank uses the first gateway heard.
Actions
- Extension Enable / Extension Disable – Enables or disables the device. A disabled device shows Disabled and raises no events.
Events
- Rain Started / Rain Stopped – The rain rate rose above 0; no rain for 10 minutes.
- Lightning Detected – A lightning strike no farther than Lightning Distance.
- Leak 1 Wet / Leak 1 Dry … Leak 4 Wet / Leak 4 Dry – That leak detector got wet; dried again.
- Wind Above Limit / Wind Below Limit – A gust reached Wind Limit; gusts fell under 80% of it.
- Temperature Above High Limit / Temperature Below High Limit – The temperature rose above High Temperature; fell back under it.
- Temperature Below Low Limit / Temperature Above Low Limit – The temperature fell below Low Temperature; rose back above it.
- Humidity Above High Limit / Humidity Below High Limit – The humidity rose above High Humidity; fell back under it.
- Humidity Below Low Limit / Humidity Above Low Limit – The humidity fell below Low Humidity; rose back above it.
- UV Above Limit / UV Below Limit – The UV index rose above UV Limit; fell back under it.
- Heavy Rain Started / Heavy Rain Stopped – The rain rate rose above Heavy Rain; fell back under it.
- Rain Today Above Limit / Rain Today Below Limit – The day’s rain passed Rain Today Limit; the day’s count started again.
- Extension Enabled / Extension Disabled – The device was enabled or disabled.
- Pin Locked / Pin UnLocked – The PIN keypad locked again, or the right PIN was entered (with a Starting Pin Code set).
Ecowitt and WS View Plus are trademarks of their respective owners. Crestron and Crestron Home are trademarks of Crestron Electronics, Inc. This extension is an independent product of Control Programming LLC and is not affiliated with, endorsed by or sponsored by the owners of Ecowitt and WS View Plus.